QUINCY HYDRONIC TECHNOLOGY Riva FP Installation Manual Page 1

Browse online or download Installation Manual for Water heaters & boilers QUINCY HYDRONIC TECHNOLOGY Riva FP. QUINCY HYDRONIC TECHNOLOGY Riva FP Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
BOILER INSTALLATION, OPERATION
INSTRUCTIONS
WALL HUNG GAS BOILER FOR
CENTRAL HEATING SUPPLY
Please Read Instructions Carefully
Save for Future Reference
Do not store or use gasoline or other ammable vapors and liquids
in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbors phone. Fol-
low the gas suppliers instructions.
If you can not reach your gas supplier call the re department.
Installation and service must be performed by a quali ed installer,
service agency or the gas supplier.
WARNING: If the information in this manual is not followed
exactly, a re or explosion may result causing property dam-
age, personal injury or loss of life.
Riva PLUS
Riva PLUS
Quincy Hydronic Technology, Inc.
3560 Lafayette Road
Bldg. 2, Unit A
Portsmouth, NH 03801
Phone: 603-334-6400
Fax: 603-334-6401
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Riva PLUS

BOILER INSTALLATION, OPERATIONINSTRUCTIONSWALL HUNG GAS BOILER FORCENTRAL HEATING SUPPLYPlease Read Instructions CarefullySave for Future Reference —

Page 2

10 RIVA PLUS MANUAL2. Parts ListPrimary Components:1 Pump2 Pump vent plug3 Automatic air purger valve4 Modulation gas valve5 Flame-detecting elect

Page 3 - Table of Contents

RIVA PLUS MANUAL 113. Internal Piping & Parts ListNote: Pressure Relief Valve (#19) should be piped to a drain or to the fl oor as lose as pos-si

Page 4

12 RIVA PLUS MANUAL4. Electric Diagrams

Page 5

RIVA PLUS MANUAL 135. Electric Diagrams Cont.Is primary circuit temp higher than selected tempRequest for heat from thermostatCirculator offIgnition

Page 6

14 RIVA PLUS MANUAL5. Installation LocationThe installation location chosen must:• Comply with all clearances listed below.• Provide suitable locat

Page 7 - IMPORTANT INFORMATION

RIVA PLUS MANUAL 156. Exhaust Pipe LocationCAUTIONEXTERNAL VENT SURFACES ARE HOT.IT IS RESPONSABILITY OF THE HOMEOWNER TO KEEP THE VENTTERMINAL CLEA

Page 8 - 1. General Information

16 RIVA PLUS MANUAL7. Mounting BracketAfter a suitable installation location is chosen, verify that the mounting wall is properly braced and strong e

Page 9

RIVA PLUS MANUAL 178. VentingThe Riva is a mechanical draft, side wall vented boiler. There are two side wall fl ue options available – separate and c

Page 10 - 2. Parts List

18 RIVA PLUS MANUALThe Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4.00and 5.00 for installation of through – the – wal

Page 11 - RIVA PLUS MANUAL 11

RIVA PLUS MANUAL 199. Venting Cont.The Riva is a mechanical draft, side wall vented boiler. There are two fl ue options available - separate and coax

Page 12 - 4. Electric Diagrams

2 RIVA PLUS MANUALDear Customer:Thank you for buying a Biasi Riva Plus Boiler System.The Riva Plus is a high effi ciency condensing, wall mounted gas

Page 13 - 5. Electric Diagrams Cont

20 RIVA PLUS MANUAL8.1 Choice of fl ue:The following fl ue kits are available for connecting to the boiler:A Standard coaxial horizontal fl ue kit (Exh

Page 14 - 5. Installation Location

RIVA PLUS MANUAL 219. Venting Cont.B Standard separate horizontal fl ue kit (Exhaust & intake outside)Figure 8.2 (Twin pipe  3.25 in)Various twi

Page 15 - 6. Exhaust Pipe Location

22 RIVA PLUS MANUAL9. Venting Cont.E Alternative separate kit (Exhaust & intake outside)Figure 8.3 (Twin Pipe  3.25 in)These kits allow for sep

Page 16 - 7. Mounting Bracket

RIVA PLUS MANUAL 239. Venting Cont.F Standard Vertical-roof kit (Exhaust & intake outside)Figure 8.4 (vertical pipe  3.1 /  4.9 in)This kit al

Page 17 - 8. Venting

24 RIVA PLUS MANUAL9. Pipe ConnectionsThe Riva boiler is supplied with a 3/4” stainless steel gas pipe (A in fi gure 10.1), 2 - 3/4” copper pipe (C,D

Page 18

RIVA PLUS MANUAL 2510. Gas Pipe ConnectionsGas supply piping is to be sized and installed properly in order to provide a supply of gas suffi -cient to

Page 19 - 9. Venting Cont

26 RIVA PLUS MANUAL11. Electrical Connections/WiringFigure 11.1 Removing Front Panel:• Remove the front panel by removing screws A and sliding the

Page 20

RIVA PLUS MANUAL 2712. Electrical Connections/Wiring Cont.11.3 Room Thermostat Connection:• The room thermostat must be connected to the terminal bl

Page 21

28 RIVA PLUS MANUAL11.5 Zone Valve Micro Switch Connection:• The zone valve micro switch must be con-nected to the terminal block situated next to t

Page 22

RIVA PLUS MANUAL 2912. Circulator Sizing12.1 Circulator capacity as a function of fl ow rate:Figure 12.1 The hydraulic specifi cation in Fig 13.1 repr

Page 23

RIVA PLUS MANUAL 3Table of ContentsSection Title Section Number Page NumberWarnings - 5-6Important Information - 7General Information 1 8Techn

Page 24 - 9. Pipe Connections

30 RIVA PLUS MANUAL13. PipingAll external piping components are to be supplied by the installer. It is very important to use a Primary Secondary pipi

Page 25 - WARNINGS

RIVA PLUS MANUAL 3113.1 Primary – Secondary Piping:All external piping components are to be supplied by the installer.It is very important to use a h

Page 26 - 26 RIVA PLUS MANUAL

32 RIVA PLUS MANUAL14. Piping Cont.13.2 Primary – Secondary Piping with Zone Valves:All external piping components are to be supplied by the installe

Page 27

RIVA PLUS MANUAL 3314. Piping Cont.13.3 Manifold Piping with Zone Valves (shown conn. to radiators):All external piping components are to be supplied

Page 28

34 RIVA PLUS MANUAL14. Commissioning14.1 Initial fi lling of the system:• Remove the front panel of the case.• Unscrew the cap on the automatic air

Page 29 - 12. Circulator Sizing

RIVA PLUS MANUAL 3515. Commissioning Cont.14.3 Checking the gas pressure at the burner:This boiler has been tested to the highest quality control sta

Page 30 - 13. Piping

36 RIVA PLUS MANUAL15. Commissioning Cont.14.4 Adjustment of the gas pressure:• Remove the front panel of the case.• Take off the lid of the sealed

Page 31 - 14. Piping Cont

RIVA PLUS MANUAL 3715. Commissioning Cont.14.6 Checking the burner ignition:• Turn the boiler OFF.• Open the gas valve outlet pressure test point 1

Page 32

38 RIVA PLUS MANUAL15. Commissioning Cont.14.8 Labels placement:Figure 14.10 Warning: The installation is not complete unless labels supplied are p

Page 33

RIVA PLUS MANUAL 3915. Commissioning Cont.14.9 Checking the fl ue system and combustion:• The fl ue system should be visually checked for soundness. Ch

Page 34 - 14. Commissioning

4 RIVA PLUS MANUALTable of ContentsSection Title Section Number Page NumberCommissioning 15 34-39Initial Filling of the System 15.1 34Lightning t

Page 35 - 15. Commissioning Cont

40 RIVA PLUS MANUAL15. Gas ConversionWARNINGS: Procedures to adapt the boiler to the type of gas available must be car-ried out by a competent and re

Page 36

RIVA PLUS MANUAL 4116. Annual Maintenance16.1 Warnings:The procedures detailed in this chapter must be carried out only by a professionally qualifi ed

Page 37

42 RIVA PLUS MANUAL17. Annual Maintenance Cont.16.4 Cleaning the primary heat exchanger:• Take off the front panel of the case, then the sealed cham

Page 38

RIVA PLUS MANUAL 43• Make sure the seals are properly seated in the female ends of the vent pipe with the fi ns facing the male end of the pipe. • R

Page 39

44 RIVA PLUS MANUAL17. Vent Part Spares17.1 Separate venting:Description Order NumberTwin pipe kit 10999.0393.0For any spare parts, please contact QH

Page 40 - 15. Gas Conversion

RIVA PLUS MANUAL 4517.2 Coaxial venting:Description Order NumberCoaxial fl ue kit 10999.0387.018. Vent Part Spares Cont.For any spare parts, please co

Page 41 - 16. Annual Maintenance

46 RIVA PLUS MANUAL17.3 Roof ventingPart Description Order NumberA Roof fl ue kit 10999.0392.018. Vent Part Spares Cont.For any spare parts, please co

Page 42 - 17. Annual Maintenance Cont

RIVA PLUS MANUAL 4718. Installer NotesSystem Checkout:Boiler Model No. ___________________Original Purchaser:________________________________________

Page 43

17962.1355.1 3808 (52A4)USAREV. 1209

Page 44 - 17. Vent Part Spares

RIVA PLUS MANUAL 5WARNINGDANGERBoiler is certifi ed as an indoor appliance. Do not install boiler outdoors or locate where it will be exposed to freez

Page 45 - 18. Vent Part Spares Cont

6 RIVA PLUS MANUALAny appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of pro-ducing carbon monoxide (CO). Carbon Mon

Page 46

RIVA PLUS MANUAL 7IMPORTANT INFORMATIONPlease read this page carefully.• ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL

Page 47 - 18. Installer Notes

8 RIVA PLUS MANUAL1. General InformationThe Riva Plus is a high effi ciency condensing, wall mounted gas boiler which provides central heat. The boile

Page 48 - REV. 1209

RIVA PLUS MANUAL 92. Technical Information Cont.ENERGY CAPACITYNominal heat input (0/2000ft)MBH 116.0Nominal heat input (2000/4500ft)MBH 110.2Minimu

Comments to this Manuals

No comments